Nuclear Power Plant - BWR

Sampling System

Monitoring reactor and other coolant water quality to prevent corrosion through automated water extraction and analysis of conductivity, pH and dissolved oxygen gas levels.

Pressure Reduction Unit

Responds to operational signals and automatically adjusts flow and pressure. Automatically performs self-clean function when process is in shut-down mode.

Cooling Unit

Double-coil type cooler offers high reliability.

Sample Hood

Manual extraction with continuous ventilation and hood shield, reduces radioactive exposure and enhances decontamination.

Analyzer Rack

Mounted unit housing electrolytic conductivity meter, pH meter, and dissolved oxygen meters.

Control Panel

Data display and controls designed for operational simplicity of pumps and valves.

Go to Top

Containment Atmosphere Monitoring System

Incident evaluation through analysis of hydrogen and oxygen gas concentrations in the containment area.

Go to Top

Post Accident Sampling System

Incident evaluation of reactor coolant quality and containment area atmosphere.

Go to Top

Dew-Point Temperature Detection System

Containment atmosphere dehumidification monitoring through dew-point temperature measurement.

Go to Top

Oxygen Injection System

Oxygen injection into feed-water for corrosion control.

Go to Top

Liquid Radwaste Neutralizing System

Automated pH treatment of liquid radwaste prior to entering evaporator.

Go to Top

Hydrogen Gas Detection System

Performance monitoring of Off Gas Recombiner System through measuring hydrazine gas concentration.

Go to Top

CUW pump

A NIKKISO's NON-SEAL Pump that specifically designed for the reactor water clean up system.

Go to Top

SLC pump

Adding more boric acid to the reactor coolant.

Go to Top

Contact

Industrial Division   Instrumentation & Power Systems Sales Department

Phone: +81-42-392-3556 / Fax: +81-42-392-3522

Contact via WebForm


Home > Products and Services > Sampling Systems and Chemical Feed Systems > Nuclear Power Plant - BWR