Nuclear Power Plant - PWR

Primaly Loop

Post Accident Sampling System

Automated extraction and analysis of cooling water and gas following an incident.

Sample Hood & Valve Panel

Increased safety with radiated water extraction. Nikkiso design minimizes contact with samples.

Primary Coolant Auto Monitoring System

Monitoring electro conductivity, pH, dissolved oxygen and dissolved hydrogen. Nikkiso's extraction process also includes an automated temperature and pressure reduction of the samples, and radioactive extraction techniques.

Boron Monitor

Monitoring boron concentration for controling nuclear reaction.

Go to Top

Secondary Loop

Chemical Feed System

Automated ammonium or hydrazine feed water injection for corrosion protection.Ammonium injection increases alkalinity. Hydrazine injection reduces oxydation.

Secondary Loop Sampling System

Automated extraction and analysis of electro conductivity, pH, sodium ion and dissolved oxygen. Nikkiso's extraction process also includes an automated temperature and pressure reduction of the samples.

Go to Top

Zinc Feed System

Increased safety through zinc replacement of radio isotopes in the loop.

Go to Top

SGBD Water Monitoring System

Monitoring electro conductivity, cation conductivity and pH.

Go to Top

Condenser Leakage Monitoring System

Leakage detection for loop protection.

Go to Top