HLK heatless dryer (low-flow)

HLK heatless dryer (low-flow)

HLK type heatless driers are compact heatless dryers designed for low flow.
The dryers are most desirable not only for industry usage but also for analysis processes and R&D in laboratories.

Reference specifications

Dew point temperature -73°C (under pressure) -40°C (under pressure)
Inlet air flow ∼700 NL/min ∼1,100 NL/min
Inlet air pressure 0.41∼0.97MPa 0.41∼0.97MPa
Inlet air temperature 10∼49°C 10∼49°C

CDA/DHA heatless dryer (medium-flow)

CDA/DHA heatless dryer (medium-flow)

CDA/DHA heatless dryers are suited not only for instrumentation air in process control but also for a wide variety of industry applications including powder pumping, coating spray, and N2 alternative air in semiconductor manufacturing process.

Features

  • Dryer-specific poppet valves are developed and used.
  • Continuous supply of air in case of power shutdown (no problem in the event of a power outage).
  • Absorbent with super-long life is employed.
  • Easy checking of conditions from the liquid crystal display system indication (when ADCBOX is selected).
  • With the adoption of dedicated valves, the purge flow rate is 14.8% (at 0.69 MPa), which is the limit level of the heatless dryer.
  • The purge flow is controlled to an proper value by an AMLOC energy saving system according to the flow load.

Reference specifications

Dew point temperature -73°C (under pressure) -40°C (under pressure)
Inlet air flow ∼37 Nm3/min ∼38 Nm3/min
Inlet air pressure 0.41∼0.99MPa 0.41∼0.99MPa
Inlet air temperature 10∼49°C 10∼49°C

CHA heatless dryer (high-flow)

CHA heatless dryer (high-flow)

CDA/DHA heatless dryers are suited not only for instrumentation air in process control but also for a wide variety of industry applications including powder pumping, coating spray, and N2 alternative air in semiconductor manufacturing process.

Features

  • Dryer-specific century valves are developed and used.
  • Continuous supply of air in case of power shutdown (no problem in the event of a power outage).
  • Absorbent with super-long life is employed.
  • Easy checking of conditions from the liquid crystal display system indication (when ADCBOX is selected).
  • With the adoption of dedicated valves, the purge flow rate is 14.8% (at 0.69 MPa), which is the limit level of the heatless dryer.
  • The purge flow is controlled to an proper value by an AMLOC energy saving system according to the flow load.

Reference specifications

Dew point temperature -73°C (under pressure) -40°C (under pressure)
Inlet air flow 26∼264 NL/min 34∼420 NL/min
Inlet air pressure 0.41∼0.99MPa 0.41∼0.99MPa